Wiki source code of Irrigation System
Last modified by Aaron Bugaj on 2022/05/03 16:48
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
1.1 | 1 | {{box cssClass="floatinginfobox" title="**Table of contents**"}}{{toc/}}{{/box}} |
2 | |||
3 | Each hill slope was designed with five (5) irrigation circuits. Each hill slope is fed via a supply line which can be charged using any of the pumps (valving restrictions apply) | ||
4 | |||
5 | = __Irrigation circuits__ = | ||
6 | |||
7 | Circuit A (MP2000) | ||
8 | - This circuit utilizes six (8) Hunter MP2000 heads providing approximately 0.32 cm/hr of rain | ||
9 | |||
10 | Circuit B (Intermediate) | ||
11 | - This circuit utilizes eight (6) Hunter MP2000 heads providing approximately 0.31 cm/hr of rain | ||
12 | |||
13 | Circuit C (MP3000) | ||
14 | - This circuit utilizes eight (8) Hunter MP3000 heads providing approximately 0.74 cm/hr of rain | ||
15 | |||
16 | Circuit D (Multi1) | ||
17 | - This circuit utilizes fourteen (14) Hunter MP2000 heads and fourteen (8) Hunter MP3000 heads providing approximately 1.37 cm/hr of rain | ||
18 | |||
19 | Circuit E (Multi2) | ||
20 | - This circuit utilizes fourteen (14) Hunter MP2000 heads and fourteen (8) Hunter MP3000 heads providing approximately 1.37 cm/hr of rain | ||
21 | |||
22 | ~*~*~* Please note ~*~** | ||
23 | Circuit D and E are designed to be identical and each is equivalent to the combination of A + B + C. | ||
24 | |||
25 | |||
26 | = __Irrigation Scenarios__ = | ||
27 | |||
28 | |A (MP2000)|B (Interm)|C (MP3000)|D (Multi1)|E (Multi2)|Rain Rate (cm/hr)|scenario # | ||
29 | ||||||0.00|0 | ||
30 | |X|||||0.31|1 | ||
31 | ||X||||0.32|2 | ||
32 | |X|X||||0.63|3 | ||
33 | |||X|||0.74|4 | ||
34 | |X||X|||1.05|5 | ||
35 | ||X|X|||1.06|6 | ||
36 | ||||X||1.37|7 | ||
37 | |X|||X||1.68|8 | ||
38 | ||X||X||1.69|9 | ||
39 | |X|X||X||2.00|10 | ||
40 | |||X|X||2.11|11 | ||
41 | |X||X|X||2.42|12 | ||
42 | ||X|X|X||2.43|13 | ||
43 | ||||X|X|2.74|14 | ||
44 | |X|||X|X|3.05|15 | ||
45 | ||X||X|X|3.06|16 | ||
46 | |X|X||X|X|3.37|17 | ||
47 | |||X|X|X|3.48|18 | ||
48 | |X||X|X|X|3.79|19 | ||
49 | ||X|X|X|X|3.80|20 | ||
50 | |X|X|X|X|X|4.11|21 | ||
51 | |||
52 | = __Irrigation Control__ = | ||
53 | |||
54 | Each of the five irrigation circuits is operated by a VALWORX electric ball valve. These valves can be opened and closed manually or by computer control. The device cRIO-LEO-Irrigation (located in the irrigation electrical control panel) is configured as a task scheduler which provides the ability to precisely automate complex valve action scenarios. More information regarding this topic can be found in the page [[Irrigation.IRRIGATION CONTROL]] | ||
55 | |||
56 | = __Water storage__ = | ||
57 | |||
58 | There are 7 tank in the east bay - each tank can hold approximately 8,037 Liters. | ||
59 | There are 4 tank in the west bay - each tank can hold approximately 9,690 liters. | ||
60 | The RO can produce approximately 75 liters per minute. | ||