This device is offered in two flow range models. In LEO the -75 model was originally used and was eventually replaced with lower flow -32 model.
No longer in production.

Seametrics PE102 (manual)

Calculation Notes

Sensor Code:PE102
Sensor:PE102 from Seametrics Inc.
Measurement:Volume of flow (Liters)
Output 1:Pulses (unit count)Range 1:0 to 600000
Output 2:Volume (L) = \frac{output1}{k}Range 2:0 to ?

For the "-075" model, k = 500 pulses per liter. For the low flow "-032" model, k = 1000 pulses per liter.

Wiring Diagram

PE102_Wiring_Schematic.png