1 ==== Data Acquisition Hardware ====
2
3 National Instruments hardware
4
5 * [[NI-9074: (National Instruments) Compact Re-configurable Input/Output real-time computer with FPGA>>http://sine.ni.com/nips/cds/view/p/lang/en/nid/203964||rel="noopener noreferrer" target="_blank"]]
6 * NI-9205: 32/16 CH 10V analog input module
7 * NI-9213: 16 CH 80mV analog input module (Thermocouples & low voltage signals)
8 * NI-9217: 4 CH 100 ohm RTD analog input moduleĀ 
9 * NI-9237: 4 CH Half/Full bridge analog input module
10 * NI-9201: 8 CH digital I/O module
11 * NI-9403: 32 CH digital I/O module
12 * NI-9422: 8 CH 24V digital input module
13 * NI-9472: 8 CH 24V digital output module
14
15 Custom hardware and equipment
16
17 * [[Aztera SDI-12 power & signal junction board>>doc:LEO.AzteraBOB]]
18 * [[B2 DVI7911 power & signal junction board>>doc:DVI7911_JunctionBoard]]
19
20 ==== Instrument (data-logging & control) electrical panels ====
21
22 * [[P01>>doc:DSC.IntrumentPanel01]] - Monitors drainage, lower 1/3 heat flux plates & TCAVs, lower 1/2 CO2 probes, and lower 4 load cells
23 * [[P02>>doc:DSC.IntrumentPanel02]] - Monitors middle 1/3 heat flux plates & TCAVs, middle 2 load cells, and entire SDI-12 network.
24 * [[P03>>doc:DSC.IntrumentPanel03]] - Monitors upper 1/3 heat flux plates & TCAVs, upper 1/2 CO2 probes, upper 4 load cells, and sensors on upper two above ground masts.
25 * [[P04>>doc:DSC.IntrumentPanel04]] - Monitors sensors on the bottom three above ground masts.
26 * [[Irrigation>>doc:DSC.IntrumentPanelIrrigation]] - Monitors inbound water flow and valve states, and controls electric valves.
27 * [[GasSampling>>doc:DSC.InstrumentPanelGas]] - Performs above ground gas sampling (using the LI-7000) for the hill slopes and controls soil gas valves.