2
3 The ERT system is composed of 120 electrodes. They are arranged in 24 stacks of 5 electrodes. A diagram of the electrode stack is shown below.
4
5 = Calculation Notes =
6
7 There are no calculation notes for these sensors.
8
9 = Wiring Diagram =
10
11 [[image:ERT-Schematic.png||style="display: block; margin-left: auto; margin-right: auto; width="]]
12
13 = Other Notes =
14
15
16 The electrodes are connected via gold plated pins (Millmax, part # 3601-1-07-21-00-00-08-0) to 22 AWG (7/30 strand) tinned copper wire. The wire is part of a 5-conductor cable (AlphaWire, part # 1175C, rated at 300V) color coded as follows:
17
18 1 – Green – closest to surface
19 2 – Orange
20 3 – Red
21 4 – White
22 5 – Black – closest to deck
23
24 The cable is PVC jacketed. In order to counter any negative effects of PVC in the soil, the cable is sleeved in 5/16” Teflon tubing. This creates a physical barrier between the PVC jacket and the soil. Pins are glued in place using DP190 or DP110 epoxy from 3M, joints are connected using DP190